Cyrix battery combiners are an excellent replacement for diode isolators. Their main feature is that they do not cause any voltage drop. Therefore, the output voltage of alternators or battery chargers does not need to be increased. System voltage 12-24V up to a maximum of 120A charging with self-alignment - Automatically disconnects the battery when minimum voltages are reached or excessive fluctuations in discharge are detected, and reconnects automatically as soon as it detects the following voltages: 13V for 12V systems and 26V for 24V systems, indicating that the battery is charging - Charging priority to the starter battery - Bidirectional voltage detection and power supply from both batteries - Features: Switching voltage and currents: 12V-24V 120A - Self-consumption: 12V= 220mA 24V= 120mA - Disconnection voltage: 11 V to 12.8 V and 22 V to 25.7 V - Connection voltage: With intelligent trend detection from 13 V to 13.8 V and from 26 V to 27.6 V with intelligent trend detection - StartAssist: Yes (Cyrix remains active for 30 seconds) - Connection bolts and connection cables: 13mm (M6) - Protection type: IP54 - Dimensions (h x w x d) in mm: 46 x 46 x 80